P7100 Plunger Lift Timing

Bosch P7100 Lift Specs (mm)
P7100 Pumps Only
Tolerance for Plunger Lift Timing is +/- 0.1mm
( Use CPL number from engine data plate )

Engine Model

B5.9
160hp
Except CPL 1968

B5.9
160hp
CPL 1968 Only

B5.9
180hp

B5.9
215hp

B5.9
California

CPL Numbers

1549, 1550
1551, 1552
1553, 1815
1816, 1959
1839

1968

2022, 2174

2023, 2175

1863

Static
Injection
Timing
degrees BTDC

Lift in mm

Lift in mm

Lift in mm

Lift in mm

Lift in mm

9.5°

5.15

10.0°

5.25

10.5°

5.35

11.0°

5.45

4.0

11.5°

5.55

4.05

4.7

4.0

12.0°

5.65

4.15

4.1

4.8

4.1

12.5°

5.7

4.2

4.2

4.9

4.2

13.0°

5.8

4.3

4.3

5.0

4.3

13.5°

5.9

4.4

4.4

5.1

4.4

14.0°

6.0

4.5

4.5

5.2

4.5

14.5°

6.1

4.6

4.6

5.3

4.6

15.0°

6.2

4.7

4.7

5.4

4.7

15.5°

6.3

4.8

4.8

5.5

4.8

16.0°

6.4

4.9

4.9

5.6

4.9


* TSB 18-11-96 Remark CPL 2022 to 2174 and time at 14° ( 4.5mm )
* TSB 18-11-96 Remark CPL 2023 to 2175 and time at 13.5° ( 5.1mm )

* TSB 18-11-96 CA. Mod add +1° ( CPL 1863 )